Popular Articles
Updating Vesper Firmware
Requirements prior to starting Vesper and accompanying MicroSD card Vesper battery charged > 30% Computer / laptop with internet access to download firmware Time, process may take up to 30 minutes Part I: Prepare MicroSD card Remove MicroSD card from ...
Updating Vision1 GCS Software (QGC)
Required prior to starting: Vision GCS charged to 50% or higher USB-A thumbstick (flash drive) loaded with GCS software see Vantage Robotics Vision GCS Flash Drive updater USB-A to USB-C adapter GCS Update instructions Turn on Vision GCS Log in to ...
What is the expected Vesper battery lifetime?
Battery lifetime is measured by how many cycles of full charge and discharge it takes to get down to 80% max battery capacity. For the Vesper Endurance Battery, internal testing shows that this is more than 500 cycles. The battery will still be ...
How to extract telemetry logs from Vision GCS
Flight data are stored in Vesper's internal memory when the "Vehicle Flight Logging" parameter is enabled after the aircraft has been armed. The flight data log contains information about various aircraft conditions such as motor speed, battery ...
Change Video Resolution for low-light conditions
Change Video Resolution for low-light conditions Power on Vesper Power on Vision GCS Log in to Vision if necessary Tap the Camera “Settings” icon below the red camera shutter button Locate the “Video Resolution” section in the Video Settings dialog ...